Jim Adams Jim Adams
0 Course Enrolled • 0 Course CompletedBiography
Test CFPE Engine, CFPE Valid Dumps Ebook
However, SurePassExams saves your money by offering CFPE real questions at an affordable price. In addition, we offer up to 12 months of free CFPE exam questions. This way you can save money even if CFPE introduces fresh Certified Fire Plan Examiner (CFPE)Exam CFPE exam updates. Purchase the NFPA CFPE preparation material to get certified on the first attempt.
Although at this moment, the pass rate of our NFPA CFPE exam braindumps can be said to be the best compared with that of other exam tests, our experts all are never satisfied with the current results because they know the truth that only through steady progress can our Certified Fire Plan Examiner (CFPE)Exam CFPE Preparation materials win a place in the field of exam question making forever.
100% Pass Quiz 2025 NFPA CFPE Perfect Test Engine
For candidates who are going to buy CFPE study materials online, they may care much about the private information. We respect the privacy of you, and we can ensure you that if you CFPE study materials from us, your personal information such as your name and email address will be protected well. Once the order finishes, your information will be concealed. In addition, CFPE Exam Materials are high quality, since we have a professional team to check the questions and answers. Online and offline chat service stuff is available, if you have any questions about CFPE study materials, don’t hesitate to contact us.
NFPA Certified Fire Plan Examiner (CFPE)Exam Sample Questions (Q95-Q100):
NEW QUESTION # 95
If a sprinkler system is supplied with water from a gravity tank, the gravity tank shall be installed in accordance with what standard in order to be acceptable as a source of water?
- A. NFPA24
- B. NFPA13
- C. NFPA20
- D. NFPA22
Answer: D
Explanation:
If a sprinkler system is supplied with water from a gravity tank, the tank must be installed in accordance with NFPA 22, Standard for Water Tanks for Private Fire Protection. NFPA 22 provides the requirements for the design, construction, installation, and maintenance of water tanks used for fire protection. It ensures that the gravity tank meets the necessary standards to be a reliable and effective water source for the sprinkler system.
Top of Form
Bottom of Form
NEW QUESTION # 96
Where field conditions necessitate a substantial change in the approved plans,
- A. no action is necessary on the part of the applicant.
- B. no action is necessary on the part of the AHJ.
- C. revised drawings may be required by the AHJ.
- D. revised drawings must be submitted to the applicant.
Answer: C
Explanation:
When field conditions necessitate a substantial change in the approved plans, the Authority Having Jurisdiction (AHJ) may require revised drawings. This ensures that any modifications still comply with the relevant fire codes and safety standards. The AHJ has the responsibility to ensure that all changes maintain the intended level of safety and that they are accurately documented and reviewed.
NEW QUESTION # 97
What is the permitted fire flow reduction for two buildings on the same lot with a separation of 40 ft (12 m)?
- A. 25 percent
- B. 40 percent
- C. 33 percent
- D. 50 percent
Answer: A
Explanation:
For two buildings on the same lot with a separation of 40 ft (12 m), a fire flow reduction of 25 percent is permitted. This reduction is typically allowed under the guidelines of NFPA standards or local fire codes, which consider the distance between structures and the associated fire risk. A separation of 40 feet is sufficient to warrant a 25 percent reduction in required fire flow, assuming that other fire safety measures, such as sprinkler systems, are in place.
NEW QUESTION # 98
Exhibit.
In the figure what would be the minimum diagonal distance between stairways 1 and 2?
- A. 43 ft 9 in (13.3 m)
- B. 37 ft 3 in. (11.3m)
- C. 22 ft 4 in (6.8 m)
- D. 29 ft 2 in (8.9 m)
Answer: B
Explanation:
To determine the minimum diagonal distance between stairways 1 and 2, we need to calculate the diagonal length of the path between points A and H on the provided floor plan. According to NFPA 1031, Plan Examiners must verify egress routes to ensure compliance with NFPA standards, particularly regarding the minimum distance between exits to ensure that a fire in one location does not cut off access to an alternative exit.
Using the Pythagorean theorem for diagonal distance in a rectangular area, the calculation between stairways A (Stairway 1) and H (Stairway 2) is as follows:
Distance=(Length2+Width2) ext{Distance} = sqrt{(Length